Hardware Installation
Begin the installation by mounting the cabinet in a dry protected area with access to unswitched AC power. Install Hardware in the sequence indicated below. Do NOT apply power until installation is complete.
NOTE: All wiring entry points are designated by arrows. All circuits are classified UL power limited except for the battery leads.
Minimum 1/4” (6.4mm) separation must be maintained at all points between power limited and non-power limited wiring and connections.
1. Keybus Wiring
The 4-wire KEYBUS (red, black, yellow and green) is the communication connection between the control panel and all modules. The 4 KEY- BUS terminals of all modules must be connected to the 4 KEYBUS terminals of the main control panel.
The following rules must be followed when wiring the Keybus:
Pc1616 Pc1832 Pc1864 User Manual V4.5 And Higher Learning
•
Modules can be home run, connected in series or can be T- tapped provided that the maximum wire distance from the control panel to any module does not exceed 1,000 feet (305m)
•
No more than 3,000 feet (915m) of wire can be used in total
2. Zone Wiring
Zones can be wired for Normally Open, Normally Closed Contacts with Single-end-of-line (SEOL) resistors or Double End-of-Line (DEOL) resistors. Observe the following guidelines •
For UL Listed Installations use SEOL or DEOL only.
•
Minimum 22 AWG wire, maximum 18 AWG
•
Fronius TransPuls Synergic 5000 Pdf User Manuals. View online or download Fronius TransPuls Synergic 5000 Operating Instructions & Spare Parts. Fronius transpuls synergic 5000 user manual. Fronius TransSynergic 5000 Pdf User Manuals. View online or download Fronius TransSynergic 5000 Operating Instructions Manual, Operating Instructions & Spare Parts, Service Manual.
Do NOT use shielded wire
•
Wire run resistance shall not exceed 100
Ω.
Refer to the chart
below.
•
Section [001-004] Selects Zone Definition
•
Section [013] Opt [1] Selects Normally Closed or EOL resistors
•
Section [013] Opt [2] Selects Single EOL or Double EOL resis- tors.
Zone Status
Loop Resistance - 0
Ω (shorted wire/loop)
- 5600
Ω (contact closed)
- infinite (broken wire, open) - 11,200
Ω (contact open)
Loop Status Fault Secure Tamper Violated
3. Bell Wiring
These terminals supply 700mA of current at 12V
DC
Instruction Manual
for commercial
installations and 11.1-12.6 V
DC
for residential installations (e.g.DSC
SD-15 WULF). To comply with NFPA 72 Temporal Three Pattern requirements:
Program Section [013] Opt [8]ON.
The Bell output is supervised and power limited. If unused, connect a 1000
Ω resistor across Bell+ and Bell- to prevent the panel from dis-
playing a trouble. See [
✱][2].
NOTE: Bell output is current lim- ited by 2A PTC
NOTE: Steady, Pulsed and Tem- poral Three Pattern alarms are supported.
CONTROL
PANEL
150’ (46m)
150’ (46m)
Pc1616 Pc1832 Pc1864 User Manual V4.5 And Higher Student
500’ (152m)
500’ (152m)
Normally Closed Loops - Do NOT use for UL Installations
Single End-of-Line Resistor Wiring
Double End-of-Line Resistor Wiring
OBSERVE
POLARITY
User Manual For Iphone
BELL/SIREN 700mA (max.)